switch# show fex 101
FEX: 101 Description: FEX0101 state: Online
FEX version: 7.3(0)N1(1) [Switch version: 7.3(0)N1(1)]
Extender Serial: FOC1727R1GX
Extender Model: N2K-B22HP-P, Part No: 73-13780-05
Bay: 1
Rack: KylesHugeRack
Enclosure: OA-0026551CFDCD
Enclosure Serial: USE952WAFA
Rack Id: Default RUID
Pinning-mode: static Max-links: 1
Fabric port for control traffic: Eth1/1
FCoE Admin: false
FCoE Oper: true
FCoE FEX AA Configured: false
Fabric interface state:
Po101 – Interface Up. State: Active
Eth1/1 – Interface Up. State: Active
Eth1/2 – Interface Down. State: Configured
Eth1/3 – Interface Down. State: Configured
Eth1/4 – Interface Down. State: Configured
switch# show ver fex 101
Software
Bootloader version: 0.2
System boot mode: primary
System image version: 7.3(0)N1(1) [build 7.3(0)N1(1)]
Hardware
Module: Fabric Extender 16x10GE + 8x10G Module
CPU: Motorola, e300c4
Serial number: FOC1728175E
Bootflash: locked
Kernel uptime is 0 day(s), 0 hour(s), 5 minutes(s), 41 second(s)
Last reset at Sat Aug 17 15:18:24 2013
Reason: Kernel Reboot
Service: Reload new image
switch# show diagn res fex 101
FEX-101: Fabric Extender 16x10GE + 8x10G Module SerialNo : FOC1727R1GX
Overall Diagnostic Result for FEX-101 : OK
Test results: (. = Pass, F = Fail, U = Untested)
TestPlatform:
0) SPROM: —————> .
1) Inband interface: —————> .
2) Fan: —————> U
3) Power Supply: —————> U
4) Temperature Sensor: —————> .
Eth 1 2 3 4 5 6 7 8
Port ————————-
. . . . . . . .
Eth 9 10 11 12 13 14 15 16
Port ————————
. . . . . . . .
TestFabricPorts:
Fabric 1 2 3 4 5 6 7 8
Port ————————-
. . . . . . . .
switch# show env fex 101
Temperature Fex 101:
—————————————————————–
Module Sensor MajorThresh MinorThres CurTemp Status
(Celsius) (Celsius) (Celsius)
—————————————————————–
1 Outlet-1 85 75 40 ok
1 Outlet-2 85 75 43 ok
1 Inlet-1 85 75 31 ok
1 Inlet-2 85 75 28 ok
1 Die-1 110 105 51 ok
switch# show inv fex 101
NAME: “FEX 101 CHASSIS”, DESCR: “N2K-B22HP-P CHASSIS”
PID: N2K-B22HP-P , VID: V01 , SN: FOC1727R1GX
NAME: “FEX 101 Module 1”, DESCR: “Fabric Extender Module: 16x10GE, 8x10GE Supervisor”
PID: N2K-B22HP-P , VID: V01 , SN: FOC1728175E
OA-0026551CFDCD> show interconnect info 1
- Ethernet
Product Name: Cisco Fabric Extender for HP BladeSystem
Width: Single
URL to Management interface:
In-Band IPv4 Address: 0.0.0.0
User Assigned Name: fex-101
Part Number: 641146-B21
Spare Part Number: 708078-001
Serial Number: FOC1727R1GX
Temperature Sensor: Present
JS2 Connector: Absent
Internal Ethernet Interface to OA: Absent
Internal Ethernet Route to OA: Enabled
Internal Serial Interface to OA: Absent
Internal Serial Route to OA: Enabled
External Serial Port Interface: Absent
External Ethernet Interface: Absent
Manufacturer: HP
OA-0026551CFDCD> show interconnect status 1
Interconnect Module #1 Status:
Status : OK
Thermal: OK
CPU Fault: OK
Health LED: OK
UID: Off
Powered: On
Diagnostic Status:
Internal Data OK
Management Processor OK
Thermal Warning OK
Thermal Danger OK
Power OK
Device Failure OK
Device Degraded OK
OA-0026551CFDCD> show interconnect list
Bay Interconnect Type Manufacturer Power Health UID Management IP
— —————– ——————– ——- ——— — —————
1 Ethernet HP On OK Off 0.0.0.0
2 Ethernet HP On OK Off 0.0.0.0
3 Ethernet HP On OK Off 0.0.0.0
4 Ethernet HP On OK Off 0.0.0.0
5 Ethernet HP On OK Off 0.0.0.0
6 Ethernet HP On OK Off 0.0.0.0
7 [Absent]
8 [Absent]